TrueTooth #18 (02)
TrueTooth #18 (02)
TrueTooth #18 (02)
TrueTooth #18 (02)
TrueTooth #18 (02)

TrueTooth #18 (02)

All of our 3d printed TrueJaw and TrueTooth products, along with our file retrieval and hand instruments are now sold through PlanB Dental. Please visit www.planbdental.com to learn more and to purchase.

TrueTooth #18-002 has relatively large canals and very significant curvatures.  The mesial canals have swooping, severe curvature, joining to an exit of 0.18 mm.  The distal canal has a severe apical impediment and corkscrew bend 2 mm from the terminus.

Sold in a pack of 5.

+
No. of Roots No. of Canals Difficulty Factor
2 3 4
Root Curvature M - Severe, D - Slight
Coronal Canal Curvature M - Severe, D - Slight
Apical Canal Curvature M - Slight, D - Severe Bend
Pulp Chamber Size Medium
Coronal Canal Size Large
Apical Canal Size Small
Terminal Diameter M - 0.18 mm, D - 0.22 mm
Fins None
Apical Confluence MB, ML
Coronal Impediments None
Apical Impediments M - Slight, D - Very Severe

TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth.  TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA.  Special handling is necessary to realize the maximum benefits of using TrueTooth.

Access:

  • Use handpieces at 1,000 RPM with no torque limit.
  • Ultrasonics are not ideal, but work best when used wet.

Negotiation:

  • Negotiate as normal using a lubricant.

Shaping:

  • Use handpieces at normal RPM and torque settings.

Irrigation:

  • Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.

Obturation:

  • Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
  • Carrier-based obturation: obturate as normal.

Radiographs:

  • Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.

Helpful Tip:

  • Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.

Description

No. of Roots No. of Canals Difficulty Factor
2 3 4
Root Curvature M - Severe, D - Slight
Coronal Canal Curvature M - Severe, D - Slight
Apical Canal Curvature M - Slight, D - Severe Bend
Pulp Chamber Size Medium
Coronal Canal Size Large
Apical Canal Size Small
Terminal Diameter M - 0.18 mm, D - 0.22 mm
Fins None
Apical Confluence MB, ML
Coronal Impediments None
Apical Impediments M - Slight, D - Very Severe


Instructions for Use 

TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth.  TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA.  Special handling is necessary to realize the maximum benefits of using TrueTooth.

Access:

  • Use handpieces at 1,000 RPM with no torque limit.
  • Ultrasonics are not ideal, but work best when used wet.

Negotiation:

  • Negotiate as normal using a lubricant.

Shaping:

  • Use handpieces at normal RPM and torque settings.

Irrigation:

  • Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.

Obturation:

  • Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
  • Carrier-based obturation: obturate as normal.

Radiographs:

  • Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.

Helpful Tip:

  • Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.