TrueTooth #18 (03) - Shaped Prosthodontic
TrueTooth #18-003-SP has been accessed and shaped to a 55-.08 in the distal and a 40-.06 shape in the confluent mesial canals. Use this TrueTooth to practice filling methods and post-endodontic restorative procedures, including post and core techniques.
Sold in a pack of 5.
- Description
-
Instructions for Use
No. of Roots | No. of Canals | Difficulty Factor |
2 | 3 | 2 |
Root Curvature | M - Severe, D - Moderate |
Coronal Canal Curvature | M - Moderate, D - Slight |
Apical Canal Curvature | M - "S" Curve to the M, D - Moderate Curve to the DB |
Pulp Chamber Size | Partially missing due to carious destruction |
Coronal Canal Size | Large |
Apical Canal Size | Small |
Terminal Diameter | M - 0.60 mm, D - 0.57 mm |
Fins | None |
Apical Confluence | Mesial Canals |
Coronal Impediments | None |
Apical Impediments | None |
TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth. TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA. Special handling is necessary to realize the maximum benefits of using TrueTooth.
Access:
- Use handpieces at 1,000 RPM with no torque limit.
- Ultrasonics are not ideal, but work best when used wet.
Negotiation:
- Negotiate as normal using a lubricant.
Shaping:
- Use handpieces at normal RPM and torque settings.
Irrigation:
- Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.
Obturation:
- Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
- Carrier-based obturation: obturate as normal.
Radiographs:
- Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.
Helpful Tip:
- Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.
Description
No. of Roots | No. of Canals | Difficulty Factor |
2 | 3 | 2 |
Root Curvature | M - Severe, D - Moderate |
Coronal Canal Curvature | M - Moderate, D - Slight |
Apical Canal Curvature | M - "S" Curve to the M, D - Moderate Curve to the DB |
Pulp Chamber Size | Partially missing due to carious destruction |
Coronal Canal Size | Large |
Apical Canal Size | Small |
Terminal Diameter | M - 0.60 mm, D - 0.57 mm |
Fins | None |
Apical Confluence | Mesial Canals |
Coronal Impediments | None |
Apical Impediments | None |
Instructions for Use
TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth. TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA. Special handling is necessary to realize the maximum benefits of using TrueTooth.
Access:
- Use handpieces at 1,000 RPM with no torque limit.
- Ultrasonics are not ideal, but work best when used wet.
Negotiation:
- Negotiate as normal using a lubricant.
Shaping:
- Use handpieces at normal RPM and torque settings.
Irrigation:
- Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.
Obturation:
- Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
- Carrier-based obturation: obturate as normal.
Radiographs:
- Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.
Helpful Tip:
- Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.