No. of Roots No. of Canals Difficulty Factor
1 1 3

 

TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth.  TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA.  Special handling is necessary to realize the maximum benefits of using TrueTooth.

Access:

  • Use handpieces at 1,000 RPM with no torque limit.
  • Ultrasonics are not ideal, but work best when used wet.

Negotiation:

  • Negotiate as normal using a lubricant.

Shaping:

  • Use handpieces at normal RPM and torque settings.

Irrigation:

  • Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.

Obturation:

  • Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
  • Carrier-based obturation: obturate as normal.

Radiographs:

  • Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.

Helpful Tip:

  • Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.

    Description

    No. of Roots No. of Canals Difficulty Factor
    1 1 3

     

    Instructions for Use 

    TrueTooth 3D printed teeth are the exact reproduction of internal and external anatomy of extracted teeth.  TrueTooth teeth are created with special heat-resistant polymer, and proudly 3D printed in the USA.  Special handling is necessary to realize the maximum benefits of using TrueTooth.

    Access:

    • Use handpieces at 1,000 RPM with no torque limit.
    • Ultrasonics are not ideal, but work best when used wet.

    Negotiation:

    • Negotiate as normal using a lubricant.

    Shaping:

    • Use handpieces at normal RPM and torque settings.

    Irrigation:

    • Irrigate as normal using NaOCl in a syringe with a side-vent needle. TrueTooth canal tissue will dissolve after 40 minutes of irrigation, similar to vital teeth.

    Obturation:

    • Continuous Wave or other heated obturation techniques: use heat pluggers at 175 degrees Celsius.
    • Carrier-based obturation: obturate as normal.

    Radiographs:

    • Use the shortest exposure time and the lowest KVP. After radiographing, lighten and sharpen image on screen for optimum viewing.

    Helpful Tip:

    • Use alcohol on outer surface of TrueTooth during procedure for optimum visibility. Alcohol can be used in place of NaOCl.